The Fluke 115 field technician’s digital multimeter measures True-rms voltage and current with plus resistance continuity frequency and capacitance to meet the needs of a wide variety of field service technicians.
The 115 digital multimeter offers the users one-handed operation and a backlit display. The large easy-to-read digits offer a 6000-count resolution. The 115 provides Min/Max/Average with elapsed time to record signal fluctuations. It also measures:
AC and DC voltage to 600V
AC and DC current to 10 A (20 A overload for 30-seconds max).
Key features
Compact True-rms digital multimeter for field service
Includes: meter holster 4 mm PVC-Insulated test lead
Easy one-handed operation of the meter
Min/Max/Average to record signal fluctuations
What's in the box:
Digital multimeter
Holster
Installed 9V battery
4 mm PVC-Insulated test lead
Quick Reference Guide
Product Specification
Specifications
Accuracy Specifications
DC millivolts
Range/resolution
600.0 mV / 0.1 mV
Accuracy
± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/resolution
6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V
Accuracy
± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 True RMS
Range/resolution
600.0 mV / 0.1 mV
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS
Range/resolution
6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/resolution
600 Ω / 1 Ω
Accuracy
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉.
General Specifications
Maximum voltage between any terminal and earth ground
600 V
Safety
IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V