Products Detail
Fluke 373 True-RMS AC Clamp Meter
- Mfr. Part No. Fluke-373
- Warranty 3-Year Limited Warranty
- Manufacturer Fluke Industrial
Price
Per unit SGD 480.0 (inclusive of GST)
Product Details
Key features
- A top performing True-RMS current clamp for AC-only current measurements to 600 A
- Measures AC and DC voltage to 600 V
- Measures resistance to 6000 Ω with continuity detection
- Offers state of the art signal processing to provide stable readings even in noisy electrical environments
Fluke 373 True RMS AC Clamp Meter does the job for any AC-only current measurement application
Fluke 373 True-RMS AC Clamp Meter is a great choice for AC-only current measurement situations. Featuring True RMS AC voltage and current measurements you can measure AC current to 600 A and AC voltage to 600V. The 373 also measures DC voltage to 600 V and resistance to 6000 Ω.
To make it even easier to use the large easy-to-read backlit display provides better visibility in dimly lit conditions. And the 373 automatically sets the correct measurement range based on the voltage present when you power up so you do not need to move the switch while taking a measurement. When you put it all together you’ll find the Fluke 373 offers everything you need plus a little more.
Other useful capabilities:
- Provides True-RMS voltage and current measurements to accurately measure non-linear signals
- Automatically selects a measurement range based on voltage present so you don’t need to change the switch positions while taking a measurement
- Presents readings on a large easy-to-read backlit display
- Features CAT IV 300 V CAT III 600 V safety ratings
- Comes with a soft carrying case and three-year warranty
- Runs on two AA alkaline batteries
What’s in the box:
- 373 True-RMS AC Clamp Meter
- (1 pair) TL75 test leads
- Soft carrying case
- Five AA Alkaline Batteries (Installed)
- Quick Reference Guide
Product Specification
| Electrical Specifications | ||
| Current measurement DC and AC 10 Hz to 100 Hz | Range | 40 A / 400 A / 2000 A / 1400 AC rms |
| Resolution | 10 mA / 100 mA / 1 A | |
| Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits |
|
| Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |
| Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |
| Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |
| Crest Factor (50/60 Hz) | Range | 40 A / 400 A / 2000 A / 1400 AC rms |
| Crest Factor1 | 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A |
|
| Current measurement AC 100.1 Hz to 1 kHz | Range | 40 A / 400 A / 2000 A; 1400 AC rms |
| Resolution | 10 mA / 100 mA / 1 A | |
| Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits |
|
| Trigger level for Inrush | 0.50 A / 5.0 A / 5 A | |
| Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A | |
| Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A | |
| Voltage measurement DC and AC 10 Hz to 100 Hz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) |
Range | 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC |
| Resolution | 1 mV / 10 mV / 100 mV / 1 V | |
| Accuracy | 1% rdg + 10 digits 1% rdg + 5 digits |
|
| Trigger level for Hz filter OFF | 0.25 V / 6 V | |
| Trigger level for Hz filter ON | 0.25 V / 6 V | |
| Voltage measurement AC 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) |
Range | 4 V / 40 V / 400 V / 600 V ac rms |
| Resolution | 1 mV / 10 mV / 100 mV / 1 V | |
| Accuracy | 3% rdg + 10 digits 3% rdg + 5 digits |
|
| Trigger level for Hz filter OFF | 0.050 V / 0.25 V / 6 V | |
| Trigger level for Hz filter ON | 0.050 V / 0.25 V / 6 V | |
| Ohms measurement | Range | 4 kΩ / 40 kΩ / 400 kΩ |
| Resolution | 0.1 Ω / 1 Ω / 10 Ω / 100 Ω | |
| Accuracy | 1.5% + 5 digits | |
| Continuity beeper | On at ≤ 30 Ω Off at ≥ 100 Ω |
|
| Frequency measurement | Measurement range | 5.0 Hz to 1 kHz |
| Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) | |
| Accuracy – 5.0 Hz to 100 Hz | 0.2% + 2 counts | |
| Accuracy – 100.1 Hz to 1 kHz | 0.5% + 5 counts | |
| Trigger level | Refer to current and voltage tables | |
| 1. Add 2% to error spec for CF > 2 | ||
| General Specifications | ||
| Batteries | Six 1.5 V AA NEDA 15 A or IEC LR6 | |
| Battery life (with typical usage, backlight off) | 100 hours | |
| Test leads | Rated to 1000 V | |
| Weight | .814 kg (1.8 lb) | |
| Jaw size | 58 mm (2.28 in) | |
| Dimensions (L x W x D) | 300 x 98 x 52 mm (12 x 3.75 x 2 in) | |
| Safety rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III | |
| Environmental Specifications | ||
| Operating temperature | 32°F to +122°F (0°C to +50°C) | |
| Storage temperature | -4°F to 140°F (-20°C to +60°C) | |
| Operating humidity | 0 to 95% (non-condensing) | |
| Operating altitude | 2000 m | |
| Storage altitude | 10,000 m | |
| IP rating | 42 (indoor use only) | |
| Drop test requirements | 1 m | |
| EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3 V/m, performance criteria B, EN61325 |
|
| Temperature coefficients | Current | 0.1% of reading per °C outside 22°C to 24°C |
| Voltage | 0.1% of reading per °C outside 22°C to 24°C | |
Product Additional Information
Product Manuals (5)
Data Sheets (1)
Subscribe to Our Newsletter
Subscribe to our newsletter & get notification about discounts.