Fluke Calibration 9144-A-P-256 Metrology Well
A portable temperature calibration instrument covering 50°C to 660°C with built-in two-channel readout for PRTs, RTDs, thermocouples, and 4-20 mA transmitters, featuring metrology-grade accuracy to ±0.01°C.
Price (excl. GST)
SGD 18,133.24
Qty
This field metrology well combines portability with precision for industrial temperature sensor calibration. Weighing under 8.2 kg, it delivers metrology performance across six key criteria: accuracy, stability, axial uniformity, radial uniformity, loading effects, and hysteresis.
Two-channel measurement supports PRT reference probes, RTD sensors, thermocouple inputs (Types J, K, T, E, R, S, M, L, U, N, C), and 4-20 mA transmitters with 24V loop power. On-board non-volatile memory stores up to 20 test records with alphanumeric IDs, block temperature, reference temperature, UUT values, error data, date, and time.
Reference thermometer readout accuracy ranges from ±0.010°C at -25°C to ±0.070°C at 660°C. Display accuracy: ±0.35°C at 50°C and 420°C; ±0.5°C at 660°C. Stability: ±0.03°C at 50°C, ±0.05°C at 660°C. Axial uniformity at 40mm depth: ±0.05°C at 50°C, ±0.5°C at 660°C. Radial uniformity: ±0.02°C at 50°C to ±0.10°C at 660°C.
Rapid temperature changes with 15-minute heating (50°C to 660°C) and 35-minute cooling (660°C to 50°C). Built-in gradient-temperature compensation ensures stable performance in unstable field environments. Dual-zone control technology guarantees consistent results across temperature extremes.
Automated thermostatic switch testing via auto or manual setup procedures. Auto mode requires only nominal switch temperature entry and runs 3-cycle calibration. Manual mode allows custom ramp rates and cycle numbers. IEC-17025 NVLAP-accredited calibration included; backed by 4:1 test uncertainty ratio.
Includes users manual, technical manual on CD, serial cable, calibration report, test leads, insert removal tool, and 6-pin DIN connector for reference probe. RS-232 interface enables computer integration; 1586A Super-DAQ automation available. Model 9930 Interface-it software (included) exports raw data to calibration reports or ASCII files.
Download Datasheet (PDF)Related Products

Rotronic
3 Wire Hygroflex1 Spacemount Transmitter without Display — HF1 — HF132-SB1XXXXXRotronic humidity and temperature transmitter designed for HVAC applications with integrated Hygromer IN-1 sensor and accuracy of <±2 %RH in wall and duct versions.
SGD 286.00

Rotronic
AC3006Service cable for ROTRONIC instruments connecting via USB interface for programming and firmware updates.
SGD 135.00

Amprobe
Amprobe THWD-3 Relative Humidity Temperature MeterDual display meter uses precision capacitance sensor to measure relative humidity (0–100%) and temperature (-4°F to 140°F) with dew point and wet bulb calculations.
SGD 341.00

Amprobe
Amprobe TMA-21HW Hotwire Anemometer with TemperatureHot wire anemometer with temperature, humidity, and data logging capabilities for HVAC/R technicians measuring air flow in residential, commercial, and industrial systems.
SGD 960.00