The Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment - even in loud, high-energy, and high-altitude locations. The 87V is designed so you can work more efficiently.
Easy-access door for fast battery changes without breaking the calibration seal
Analog bar graph for fast changing or unstable signals
Large digit display with bright, two-level backlight for easier reading in low light
Touch Hold keeps readings on display even after removing probes
The 87V lets you identify complex electrical problems fast. It supports accurate measurements on VFDs using a low-pass filter. The meter also captures intermittents as fast as 250 µS using Peak Capture. High-frequency, high-energy noise generated by large drive systems is blocked from your measurements with specially designed shielding.
Built to highest safety standards
All the inputs in the 87V are updated to the third edition of the EN 61010-1 to CAT III 1000 V and CAT IV 600 V. The meter is designed to withstand spikes of more than 8000 V. You also benefit from an audible Input Alert warning if the test leads are placed in the incorrect input jacks for the measurement being made.
Removable holster with built in test lead and probe storage for convenience
The 87V has a removeable holster that also holds a test probe during testing for easier viewing. Relative mode lets you remove test lead resistance, improving accuracy of low-resistance measurements. To make your life even easier, the 87V fits into an optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks.
Additional measurement features
The Fluke 87V is designed and built in the U.S. and comes with a lifetime warranty.
Key features
Identify complex signal problems fast
Supports accurate measurements on VFDs using a low-pass filter
Captures intermittents as fast as 250 µS with Peak Capture
What's in the box:
Fluke 87V Industrial Multimeter
TL75 Test Leads (TL175 Eur)
AC175 Alligator Clips
Holster with tilt-leg, test lead storage
80BK Temperature Probe
9V Battery (Installed)
Product Specification
Specifications
Voltage DC
Maximum voltage
1000 V
Accuracy
±(0.05% + 1)
Maximum resolution
10 µV
Voltage AC
Maximum voltage
1000 V
Accuracy
±(0.7% + 2) True RMS
AC bandwidth
20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution
0.1 mV
Current DC
Maximum amps
10 A (20 A for 30 seconds maximum)
Amps accuracy
±(0.2% + 2)
Maximum resolution
0.01 µA
Current AC
Maximum amps
10 A (20 A for 30 seconds maximum)
Amps accuracy
±(1.0% + 2) True RMS
Maximum resolution
0.1 µA
Resistance
Maximum resistance
50 MΩ
Accuracy
±(0.2% + 1)
Maximum resolution
0.1 Ω
Capacitance
Maximum capacitance>
9,999 µF
accuracy
±(1% + 2)
Maximum resolution
0.01 nF
Frequency
Maximum frequency
200 kHz
Accuracy
±(0.005% + 1)
Maximum resolution
0.01 Hz
Duty cycle
Maximum duty cycle
99.9%
Accuracy
±(0.2% per kHz + 0.1%)
Maximum resolution
0.1%
Temperature measurement
–200.0 °C – 1090 °C –328.0 °F – 1994.0 °F excluding probe
80 BK temperature probe
–40.0 °C – 260 °C –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater
Conductance
Maximum conductance
60.00 nS
Accuracy
±(1.0% + 10)
Maximum resolution
0.01 nS
Diode
Range
3 V
Resolution
1 mV
Accuracy
±(2% + 1)
Duty cycle range
Accuracy
Within ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperature
–20 °C to + 55 °C
Storage temperature
–40 °C to + 60 °C
Humidity (without condensation)
0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C)
Operating Altitude
2000 m
Safety Specifications
Overvoltage category
EN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency approvals
CE, CSA, RCM
Mechanical and General Specifications
Size
201 x 98 x 52 mm (with holster)
Weight
355 g 624 g – with holster
Display
Digital
6000 counts updates 4/sec. 19,999 counts in high–resolution mode